Energy Saving Room Heating Air to Water Heat Pump with CO2 Refrigerant

Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 80-90°C

Product Description

Basic Specifications
Model NO.
75ZW
Work Environment
Low-temperature Heat Pump
Heat Source
Air-source
Heating Type
Multi-power Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, CCC, RoHS
Compressor
Panasonic
Control
Carel
Refrigerant
R744 (CO2)
Circuit
Inverter
Circulation Type
Monobloc
Specification
14KW
HS Code
8415812000
Production Capacity
2000 Units/Year
Key Features of CO2 (R744) Heat Pump
🔥
High Temperature Output: Water can be heated up to 90°C, ideal for disinfection, cleaning, and reducing storage tank volume.
❄️
Extreme Low Ambient: Efficiently offers heat even in temperatures as low as -43°C.
📈
High Efficiency: Maximum COP of 5.5; multi-function models can reach COP 7 by providing free cooling during heat production.
🔄
Inverter Control: Dynamically adjusts power based on real-time requirements to maximize energy savings.
🧩
Modular Design: Supports combined installation to reach higher power capacities.
🛡️
Pressure Protection: Features 6 distinct layers of pressure safety protection.
Smart Defrosting: Intelligent inverter control saves up to 50% energy during the defrost cycle.
📱
Smart Controls: Wireless control supported, plus RS485/Modbus for central management.
🖐️
Digital Interface: Programmable interface with responsive touch keys.
🏗️
Monobloc Design: Simplified installation with no extra high-pressure refrigerant connection work required.
Technical Specifications
Model 7ZW 8ZW 14ZW 25ZW 40ZW 50ZW 75ZW 120ZW
Standard Temperature Condition (Ambient 20°C, Outlet 60°C)
Performance Heating Cap. kW 6.8 7.8 13.6 24 40 51 75.5 125.4
Hot Water L/H 129.9 149 259.8 458 764 974 1442 2396
COP W/W 4.5 4.58 4.6 4.5 4.4 4.5 4.5 4.7
Low Temperature Condition (Ambient 7°C, Outlet 60°C)
Performance Heating Cap. kW 5.8 7 12.1 20 35 45.6 64 95
COP W/W 3.9 4.1 4.1 4 3.7 3.8 3.8 3.9
Unit Parameters
Dimensions Length mm 520 910 910 1280 1803 1803 2046 2468
Width mm 520 430 430 800 830 830 1106 1368
Height mm 1700 1000 1000 1500 2100 2100 2300 2413
Net Weight kg 132 130 181 380 525 650 980 1350
Noise Level dB(A) 40 42 45 46 49 50 54 65
Frequently Asked Questions
What is the maximum water temperature the CO2 heat pump can provide?
The CO2 (R744) heat pump can heat water up to a maximum of 95°C, with a rated output temperature of 45-90°C depending on the application requirements.
Can this heat pump operate in extremely cold climates?
Yes, the unit is specifically designed for low-temperature environments and can efficiently provide heating even at ambient temperatures as low as -43°C.
What are the advantages of using R744 (CO2) refrigerant?
R744 is a natural refrigerant with zero ODP (Ozone Depletion Potential) and a GWP (Global Warming Potential) of 1. It allows for high-efficiency heat exchange and high-temperature water output.
How does the inverter control benefit the user?
Inverter technology allows the compressor to adjust its speed based on the actual heat demand. This prevents frequent start-stop cycles, saves energy, and extends the lifespan of the components.
What kind of control systems are supported?
The units use Carel controllers and feature a programmable digital touch interface. They support smart wireless control and central management via RS485/Modbus protocols.
Is the installation of a monobloc design difficult?
Actually, the monobloc design simplifies installation because all refrigerant components are sealed within the outdoor unit. There is no need for complex refrigerant piping on-site, only water pipe connections.

Related Products